EMC Laboratory


Comtest 3m SAC EMC chamber
  • semi-anechoic chamber with shielded control room
  • chamber door dimensions 1.2 x 2.0 m
  • floor load capacity 500 kg/m2
  • turntable diameter 1.2 m, load capacity 500 kg
  • antenna mast with antenna height adjustable from 1 m to 4 m and polarization setting
  • test table for airborne and automotive industries with measuring distance 1 m
  • camera on tripod with remote-controlled focusing
 
EM susceptibility tests:
  • frequency range 80 MHz - 18 GHz
  • field homogeneity area 1,5 m x 1,5 m at 3 m
  • field intensity up to 200 V/m (sine) in frequency range 100 MHz to 18 GHz at 1 m
 
radiated emissions measurement:
  • frequency range for emissions measurement 30 MHz - 18 GHz
  • cylindrical measurement volume with diameter 1.2 m and height 1.2 m
 
The site is equipped with:
  • measuring receiver EMI Keysight N6038A for range 20 Hz – 26.5 GHz according to CISPR 16-1-1 and MIL-STD-461
  • generator Keysight N5183B for range 9 kHz - 20 GHz with analogue and pulse modulation
  • set of Amplifier Research power amplifiers
  • set of high-gain antennas for immunity tests
  • set of antennas with preamplifiers for emissions tests
  • probe for EM field intensity measurement
 
Frankonia CIT 10/W system for conducted immunity tests
  • frequency range 10 kHz - 400 MHz
  • minimum output power 110 W
  • amplitude modulation with modulation frequency 1 Hz - 100 kHz and modulation depth 0 % - 100 %
  • pulse modulation with modulation frequency 1 Hz - 100 kHz and modulation depth 10 % - 90 %
  • current injection clamp for BCI tests (BULK)
  • set of coupling/decoupling networks – CDN (M, S, T, AF)
  • EM coupling clamp
 
Conducted emissions test system
  • measuring receiver EMI Gauss Instruments TDEMI 30M for frequency range 9 kHz - 30 MHz according to CISPR 16-1-1
  • LISN for automotive, airborne and military industries
  • two-way V-LISN according to CISPR 16-1-2
  • current measuring probe
  • capacitive voltage probe
 
ESD generator EMC Partner ESD 3000 for electrostatic discharge immunity tests
  • test voltage up to 30 kV
  • contact discharge and air discharge tests
  • discharge networks compliant with wide range of standards: 150 pF/330 Ω, 330 pF/2000 Ω, 150 pF/2000 Ω, 330 pF/330 Ω, 100 pF/1500 Ω
 
EMC Partner TRA3000 F-S-D-V system for testing immunity to transients, surges, voltage dips, short interruptions and voltage variations on the AC or DC supply voltage

Fast transients - bursts
  • according to EN 61000-4-4
  • maximum voltage 4.4 kV
  • capacitive coupling clamp
  • application into mains leads, all combinations
 
Surges
  • according to EN 61000-4-5
  • maximum voltage without load 4.1 kV
  • maximum short-circuit current 2.05 kA
  • application into mains leads
  • coupling/decoupling network for 2 pairs of symmetric communication lines
 
Voltage dips and short interruptions
  • according to EN 61000-4-11 (AC)
  • according to EN 61000-4-29 (DC)
  • adjustable autotransformer
  • programmable power supplies with pre-programmed common voltage/frequency combinations
3