EMC Laboratory
Comtest 3m SAC EMC chamber
- semi-anechoic chamber with shielded control room
- chamber door dimensions 1.2 x 2.0 m
- floor load capacity 500 kg/m2
- turntable diameter 1.2 m, load capacity 500 kg
- antenna mast with antenna height adjustable from 1 m to 4 m and polarization setting
- test table for airborne and automotive industries with measuring distance 1 m
- camera on tripod with remote-controlled focusing
EM susceptibility tests:
- frequency range 80 MHz - 18 GHz
- field homogeneity area 1,5 m x 1,5 m at 3 m
- field intensity up to 200 V/m (sine) in frequency range 100 MHz to 18 GHz at 1 m
radiated emissions measurement:
- frequency range for emissions measurement 30 MHz - 18 GHz
- cylindrical measurement volume with diameter 1.2 m and height 1.2 m
The site is equipped with:
- measuring receiver EMI Keysight N6038A for range 20 Hz – 26.5 GHz according to CISPR 16-1-1 and MIL-STD-461
- generator Keysight N5183B for range 9 kHz - 20 GHz with analogue and pulse modulation
- set of Amplifier Research power amplifiers
- set of high-gain antennas for immunity tests
- set of antennas with preamplifiers for emissions tests
- probe for EM field intensity measurement
Frankonia CIT 10/W system for conducted immunity tests
- frequency range 10 kHz - 400 MHz
- minimum output power 110 W
- amplitude modulation with modulation frequency 1 Hz - 100 kHz and modulation depth 0 % - 100 %
- pulse modulation with modulation frequency 1 Hz - 100 kHz and modulation depth 10 % - 90 %
- current injection clamp for BCI tests (BULK)
- set of coupling/decoupling networks – CDN (M, S, T, AF)
- EM coupling clamp
Conducted emissions test system
- measuring receiver EMI Gauss Instruments TDEMI 30M for frequency range 9 kHz - 30 MHz according to CISPR 16-1-1
- LISN for automotive, airborne and military industries
- two-way V-LISN according to CISPR 16-1-2
- current measuring probe
- capacitive voltage probe
ESD generator EMC Partner ESD 3000 for electrostatic discharge immunity tests
- test voltage up to 30 kV
- contact discharge and air discharge tests
- discharge networks compliant with wide range of standards: 150 pF/330 Ω, 330 pF/2000 Ω, 150 pF/2000 Ω, 330 pF/330 Ω, 100 pF/1500 Ω
EMC Partner TRA3000 F-S-D-V system for testing immunity to transients, surges, voltage dips, short interruptions and voltage variations on the AC or DC supply voltage
Fast transients - bursts
- according to EN 61000-4-4
- maximum voltage 4.4 kV
- capacitive coupling clamp
- application into mains leads, all combinations
Surges
- according to EN 61000-4-5
- maximum voltage without load 4.1 kV
- maximum short-circuit current 2.05 kA
- application into mains leads
- coupling/decoupling network for 2 pairs of symmetric communication lines
Voltage dips and short interruptions
- according to EN 61000-4-11 (AC)
- according to EN 61000-4-29 (DC)
- adjustable autotransformer
- programmable power supplies with pre-programmed common voltage/frequency combinations